Home
Shop

AJ65SBTB1-32DT3 Mitsubishi CC – Link

SERIES: CC-LINK
TYPE: REMOTE I/O COMBINED MODULE
POWER SUPPLY (V): 24
CURRENT TYPE: DC
OCCUPIED STATIONS: 1
INTEGRATED DIGITAL INPUTS: 16
INTEGRATED DIGITAL OUTPUTS: 16
RATED INPUT VOLTAGE (VDC): 24
RATED LOAD VOLTAGE (VDC): 24
OUTPUT TYPE: TRANSISTOR
OUTPUT LOGIC: SINK
WIRING: SCREW
INT. CURRENT CONSUMPTION (A): 0,06
LC Code: LC10006

Availability: In Stock
Get A Free Quote





    Manufacturer Mitsubishi Electric Product no AJ65SBTB1-32DT3 Product type CC-Link small type remote I / O unit (DC input / transistor output, terminal block) AJ65SBTB 1-32DT3 Input format DC input (plus common type) Number of input points 16 points Rated input voltage DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V) Rated input current About 5 mA Maximum number of simultaneous input points 100% ON voltage / ON current 15 V or more / 3 mA or more OFF voltage / OFF current : 3 V or less / 0.5 mA or less Input resistance About 4.7 kO Input response time OFF ? ON 0.2 ms or less (24 VDC)ON ? OFF 0.2 ms or less (24 VDC) Input isolation method Photocoupler isolation.

    Output format Transistor output (sink type) Number of output points 16 points Rated load voltage DC 24V used load voltage range DC 19.2 to 26.4 V (ripple ratio within 5%) Maximum load current 0.5 A / 1 point, 3.6 A / 1 common Maximum inrush current 1.0 A less than 10 ms Leakage current at OFF 0.1 mA or less Maximum voltage drop during ON DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A Output response time OFF ? ON 0.5ms or less ON ? OFF 1.5 ms or less (resistance load) Surge suppressor Zener diode.

    Output section External power supply Voltage DC 19.2 to 26.4 V (ripple ratio within 5%) Current 24.2 mA or less (24 VDC, when all points are ON) External load current is not included Output isolation method Photocoupler isolation Common method 32 points 1 common (terminal trapezoid 1 wire type) Withstand voltage Between DC external terminal and ground AC 500 V for 1 minute Insulation resistance DC external terminal collective to ground 500 VDC DC insulation resistance meter 10 MO or more Protection grade IP2X Station type Remote I/O station Number of occupied stations 1 station Unit power supply Voltage DC 20.4 to 26.4 V (ripple ratio within 5%) Current 60 mA or less (24 VDC, all points ON) External wiring connection method Communication part, unit power supply part 7 points 2 piece terminal block (M3 screw) I/O power supply part, input/output part 34 points Direct mounting terminal block (M3 screw) Installation location : In the control panel.

    Back to Top


      Call Now

      Product has been added to your cart